SETTING MECHANICAL CLUTCH (A5 ONLY)
- Isolate MAINS POWER.
- Remove fan from motor to expose the motor shaft (where applicable).
Ensure fan has stopped turning.
- Lock shaft using 13mm spanner and use 6mm allen key to adjust
sensitivity - Clockwise to increase force.
- Recommended maximum push force should not exceed 15kgF.
13mm
6mm
14
<15kgF