Maintenance and Lubrication Schedule
Repeat all previously listed inspection, lubrica-
tion and maintenance procedures at 750 cycle
intervals.
Consecutive
750 Cycle
Intervals
Inspect gas springs (cylinders) for wear or damage,
proper operation and positive securement
Inspect rotating pivot slide arm UHMW slide bear-
ings
Inspect vertical arm plastic covers
Inspect power cable
Mounting
Decals and Antiskid
Tighten, replace or correct as needed
Apply Door-Ease or replace if needed. See Lubri-
cation Diagram.
Resecure or replace if needed.
Resecure, repair or replace if needed.
Check to see that the lift is securely anchored to
the vehicle and there are no loose bolts, broken
welds, or stress fractures.
Replace decals if worn, missing or illegible. Re-
place antiskid if worn or missing. See Decals and
Antiskid section on pages 37-39.
4500