Floor Level and Inboard Locator Adjustments
Achieving proper oor level
positioning of the platform and
inboard locator requires a com-
bination of Floor Level switch
adjustment and inboard locator
adjustment. Both are factory set
but must be inspected during
installation procedures (will vary
per vehicle application).
Ensure the lift is positioned and
secured as specied on Quick
Reference Installation Sheet (sup-
plied with lift) panels 1 and 2. Ad-
just the Floor Level switch rst
(detailed below). Then, adjust
the inboard locator as detailed
in Inboard Locator Adjustment
Instructions (adjust only if neces-
Floor Level Switch Adjustment
Adjust the Floor Level switch
rst! (before adjusting the inboard
locator)!
The Floor Level switch stops up-
ward travel of the platform during
the Up function (activated by the
torque tube-mounted Floor Level
cam).
Position the bottom of the lift plat-
Floor Level Switch
Floor Level Cam
Torque Tube
A
Cam depressing switch.
Note: Check the oor level posi-
tion of the platform and the in-
board locator after powering the
pump. Hydraulic pressure may af-
fect platform height slightly. Fine
tuning adjustment (tweaking) of
the Floor Level switch may be
required.
sary). The inboard locator must
rest properly on the vehicle oor
for wheelchair entry and exit.
form 1" above oor level (thresh-
old mat) using the manual op
eration system. Do not operate
the lift with the electric pump dur-
ing adjustment procedures.
Loosen the clamp securing the
torque tube-mounted Floor Level
cam. Rotate the cam until the
Floor Level switch is activated
(cam depresses switch).