Braun NUVL603C Wheelchair User Manual


 
Page 4
Certification Checklist
The following operations and conditions must be functionally veried in order for the lift to be FMVSS
403/404 compliant. If an operation does not function as described or a condition is not met, follow the refer-
enced procedures to correct the problem or contact a Braun Corporation Product Support representative.
• Vehicle movement is prevented unless the lift door is closed, ensuring the lift is stowed.
1. Verify lift stowed signal (pin 9) in the 9 conductor plug on the side of the pump module has a +12 volt
signal.
2. Refer to the interlock installation instructions.
• Lift operation shall be inhibited unless the vehicle is stopped and vehicle movement is prevented.
1. Verify vehicle secure signal (pin 6) in the 9 conductor plug on the side of the pump module has a +12
volt signal.
2. Refer to the interlock installation instructions.
• The platform will not fold/stow when occupied.
- Refer to Platform Sense Calibration.
• The outer barrier will not raise if occupied.
- Refer to Outer Barrier Occupied Calibration procedure
• An audio warning (and visual warning for public use lifts) will activate if the threshold area is occupied
when the platform is a least 1" below oor level.
1. Make sure connectors to threshold mat are properly connected.
2. Call Product Support.
• Lift platform movement shall be interrupted unless the outer barrier is deployed (up).
- Check Barrier Down limit switch, wires and connector.
- Diagnostic LCD should display a value of “1” for OBAR SW when outer barrier is deployed (up).