3M™ Filters (Side-Mounted), Adapters and Retainers
Note: Only 3M™ Filters approved under NIOSH 42 CFR 84 are to be used with the 3M™ 6000 Series Full
Facepieces.
Number Product Name
501 Filter Retainer for 5N11 and 5P71 Filters
502 Filter Adapter for 2000 Series and 7093 Filters
2071 P95 Particulate Filter
2076HF P95 Particulate Filter, hydrogen fluoride, with nuisance level acid gas relief
1
2078 P95 Particulate Filter, 3M recommended for ozone protection
2
, with nuisance level
organicvapor/acid gas relief
1
2091 P100 Particulate Filter
2096
P100 Particulate Filter, with nuisance level acid gas relief
1
2097
P100 Particulate Filter, 3M recommended for ozone protection
2
, with nuisance level organic
vapor relief
1
5N11 N95 Particulate Filter
5P71 P95 Particulate Filter
7093 P100 Particulate Filter
1. 3M recommended for relief against nuisance levels of acid gas or organic vapors. Nuisance level refers to
concentrations not exceeding OSHA PEL or applicable exposure limits, whichever is lower. Do not use
for respiratory protection against acid gas/organic vapors.
2. 3M recommended for ozone protection up to 10 times the OSHA PEL or applicable government
occupational exposure limits, whichever is lower (not NIOSH approved for use against ozone)
3M particulate filters should be changed when an increase in breathing resistance is noticed.
Filters must be replaced if they become damaged, soiled or if an increase in breathing resistance occurs.
N-series filters should not be used in environments containing oils. R-series filters may be limited to 8 hours
of continuous or intermittent use if oil aerosols are present. In environments containing only oil aerosols, P-
series filters should be replaced after 40 hours of use or 30 days, whichever is first.