ASSEMBLY INSTRUCTIONS
All 3M™ 6000 Series Full Facepieces equipped with the 3M™ 6884 DIN Port Adapter (full facepiece
assemblies 6700DIN, 6800DIN and 6900DIN) can be used in any of the following configurations:
Powered Air Purifying Respirator (PAPR)
– 3M™ GVP Belt-Mounted PAPR
– 3M™ Powerflow™ Face-Mounted PAPR
– 3M™ Breathe Easy™ Belt-Mounted PAPR
Supplied Air Respirator (SAR)
– 3M™ Dual Airline
– 3M™ Air Control Devices – Continuous Flow (excluding W-3196 Air Regulating Kit and
stainless steel options)
Negative Pressure
– 3M™ Responder FR-64 Cartridge and CP3N Canister (Front-Mounted)
– 3M™ 2000 Series and 7093 Filters and 6000 Series Cartridges (Side-Mounted)
Whenever the air filtration/supply system, including responder canisters or cartridges, are attached to the
center DIN port of the 6884 DIN Port Adapter Assembly, the 3M™ 7890 Full Face Plug must be removed
from the center port and the two bayonet ports must be closed using 6880 bayonet caps and 6895 Inhalation
Port Gaskets.
Note: Make certain 3M™ 6895 Inhalation Port Gaskets are in place on the facepiece bayonet connectors
before installing filters, cartridges or breathing tubes.
3M™ 6000 Series Cartridge (Side-Mounted) Assembly
1. Align the cartridge notch with the small solid bayonet lug on facepiece and push together.
2. Turn cartridge clockwise to stop (1/4 turn). Repeat with second cartridge. (Fig. 1)
3. Check that a 6876 breathing tube gasket (gray) and 7890 plug have been installed in the center DIN port.
Fig. 1