A SERVICE OF

logo

ZQ110
Rev. 1.00
- 66 -
Mobile Printer Command Manual
GS ( L, GS 8 L
[Name]
[Format]
[Description]
[Notes]
Select graphics data
ASCII
GS
(
L
pL
pH
m
fn
[parameter]
Hex
1D
28
4C
pL
pH
m
fn
[parameter]
Decimal
29
40
76
pL
pH
m
fn
[parameter]
ASCII
GS
8
L
p1
p2
p3
p4
m
fn
[parameter]
Hex
1D
38
4C
p1
p2
p3
p4
m
fn
[parameter]
Decimal
29
56
76
p1
p2
p3
p4
m
fn
[parameter]
This command processes graphics data according to the function code(fn).
fn
Format
Function No.
Function
0, 48
GS ( L pL pH m fn
Function 48
Transmits the NV graphics
memory capacity.
2, 50
GS ( L pL pH m fn
Function 50
Prints the graphics data in
the print buffer.
3, 51
GS ( L pL pH m fn
Function 51
Transmits the remaining
capacity of the NV graphics
memory.
64
GS ( L pL pH m fn d1 d2
Function 64
Transmits the defined NV
graphics key code list.
65
GS ( L pL pH m fn d1 d2 d3
Function 65
Deletes all NV graphics data.
66
GS ( L pL pH m fn kc1 kc2
Function 66
Deletes the specified NV
graphics data.
67
GS ( L pL pH m fn a kc1 kc2 b
xL xH yL yH [c d1...dk]1...[c d1
dk]b
Function 67
Defines the raster graphics
data in the non-volatile
memory.
69
GS ( L pL pH m fn kc1 kc2 x y
Function 69
Prints the specified NV
graphics data.
112
GS ( L pL pH m fn a bx by c xL
xH yL yH d1...dk
Function 112
Stores the raster graphics
data in the print buffer
memory.
This command is adapted to print image data.
pL, pH specifies the number of bytes following pH using (pL + pH x 256).
Since frequent writing operation could cause the damage to the NV
memory, it is recommended to write only when being required.
While storing data by this command, the printer is in BUSY state where
receiving of data is not available. Therefore, it is not recommended to
send data during this process.
The real time commands and ASB operations are not allowed during NV
memory operation process.