A SERVICE OF

logo

ZQ110
Rev. 1.00
- 42 -
Mobile Printer Command Manual
<Function 067> GS ( k pL pH cn fn n (fn=67)
[Format]
[Range]
[Default]
[Description]
[Notes]
ASCII
GS
(
k
pL
pH
cn
fn
n
Hex
1D
28
6B
03
00
30
43
n
Decimal
29
40
107
3
0
48
67
n
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=48
fn=67
2 ≤ n ≤ 3
n=3
Specifies the width of a module of PDF417 symbol.
Settings of this function affect the processing of Functions 081.
The setting unit differs, depending on the printer models.
This function is effective until ESC @ is executed, the printer is reset, or
the power is turned off.
<Function 068> GS ( k pL pH cn fn n (fn=68)
[Format]
[Range]
[Default]
[Description]
[Notes]
ASCII
GS
(
k
pL
pH
cn
fn
n
Hex
1D
28
6B
03
00
30
44
n
Decimal
29
40
107
3
0
48
68
n
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=48
fn=68
2 ≤ n ≤ 4
n=3
Specifies the module height of PDF417 symbol.
- Specify the height to [a module width x n].
Settings of this function affect the processing of Functions 081.
This function is effective until ESC @ is executed, the printer is reset, or
the power is turned off.
<Function 069> GS ( k pL pH cn fn m n (fn=69)
[Format]
[Range]
ASCII
GS
(
k
pL
pH
cn
fn
m
n
Hex
1D
28
6B
04
00
30
45
m
n
Decimal
29
40
107
4
0
48
69
m
n
(pL + pH x 256) = 4 (pL=4, pH=0)
cn=48
fn=69
m=48
48 ≤ n ≤ 8 [m=48]