Handling and reporting error conditions relating to the updating of S.M.A.R.T.
logs and S.M.A.R.T. Attributes is accomplished the same as handling error
conditions experienced while saving user data. Likewise, handling and reporting
error conditions relating to other processes (including background processes)
that occur while updating S.M.A.R.T. logs and S.M.A.R.T. Attributes is
accomplished the same as handling such error conditions while saving user data.
S.M.A.R.T. logs are validated by affecting the events being detected and logged;
the S.M.A.R.T. log always reflects the event that occurred, whether that event is
injected artificially or occurs independently.
5.1.3 S.M.A.R.T. Attributes
5.1.3.1 Supported (Baseline) Attributes
The following table shows the supported S.M.A.R.T. attributes.
Table 5-5: Baseline S.M.A.R.T. Attribute Summary
ID
Hex
Attribute Name
Description
1
0x01
Raw Read Error Rate
Raw error rate related to ECC errors.
Correctable and uncorrectable RAISE errors
are included in the error event count. (UECC
+ URAISE)
5
0x05
Retired Block Count
Tracks the total number of retired blocks.
9
0x09
Power-On Hours (POH)
Count of hours in power-on state. The raw
value of this attribute shows total count of
hours in power-on state.
12
0x0C
Device Power Cycle Count
This attribute indicates the count of full hard
disk power on/off cycles.
171
0xAB
Program Fail Count
Counts the number of flash program failures
172
0xAC
Erase Fail Count
Counts the number of flash erase failures
174 0xAE Unexpected Power Loss
Count
Counts the number of unexpected power loss
events since the drive was deployed.
177 0xB1 Wear Range Delta Returns the percentage difference in wear
between the most worn block and the least
worn block.
181 0XB5 Program Fail Count (Identical to Attribute 171)
182
0XB6
Erase Fail Count
(Identical to Attribute 172)
187
0xBB
Reported Uncorrectable
Errors
This attribute tracks the number of
uncorrectable RAISE (URAISE) errors
reported back to the host for all data access
commands.
194
0xC2
Temperature
Temperature assuming an on-board sensor
connected via Industry Standard Two Wire
Interface (ISTW) interface to the controller.
195 0xC3 ECC On the Fly Count This attribute tracks the number of
uncorrectable errors (UECC).
196 0xC4 Reallocation Count This attribute tracks the # of blocks failing
programming which are reallocated.