Initial Pump Set-Up 7 Operation
46 User Manual RKP-II (CA53461-001; Version 1.0, 10/07) © 2007 Moog GmbH
The information in the following table refers to Ö Fig. 10, Page 21
Procedure:
1. Set the adjusting screws of the mechanical stroke adjustment and
tighten them.
- Tightening torque Ö Tab. 10, Page 46
2. Secure the adjusting screws with SEAL-Lock
®
sealing nuts SW 24
(M16x1.5).
- Tightening torque M
A
= 200 Nm ± 10 Nm.
3. Attach a note that the seal capacity can no longer be guaranteed after
loosening them five times.
- If required: replace SEAL-Lock
®
sealing nut.
7.1.2.4 Servo Control, C1
Fig. 24: Servo Control, C1
Displacement V [cm
3
/U] 1932456380100140
Pos.1 WS8 = 15Nm + 5Nm WS8 = 25Nm + 5Nm
Pos. 2 WS 24 = 200 Nm ± 10 Nm
V for 1 mm adjusting screw travel
(pitch 1.5 mm/R)
3.6 5.6 6.5 8.9 11.3 11.5
Tab. 10: Mechanical Stroke Adjustment
Information about the Servo Control:
Ö Chap. "3.5.7 Servo Control, C1", Page 22
The zero position and the end position are set at the factory. Manual or
mechanical operations are performed using the adjustment lever.
Pos. Description
1 Zero position (set at the factory)
2 End position / ±V
max.
(set at the factory)
Displacement V [cm
3
/R] 1932456380100
Angle α [°] 444757445656
Control torque M [Nm] Zero position 1.2 1.6
End position 1.6 1.7 2.4 2.6 2.6
max. 8
Tab. 11: Adjustment Torque Servo Control