A SERVICE OF

logo

Preserving the Pump 5 Transport and Storage
32 User Manual RKP-II (CA53461-001; Version 1.0, 10/07) © 2007 Moog GmbH
Procedure:
1. Inspect to assure that all openings have been closed using flange covers
or caps.
2. Check to assure that transportation protection means are attached to the
pump's drive shaft.
3. Make certain that the storage space
- Is clean, dry, frost-protected and free of corrosives and vapors.
- Has a consistent temperature (temperature difference < 10 °C).
4. Depending on storage duration: preserve the pump
Ö Tab. 5, Page 31
5. Check the storage conditions
Ö Tab. 6, Page 31
6. After delivery: No steps need to be taken.
7. After demounting: Pour a small amount of mineral oil into the pump's
interior.
5.4 Preserving the Pump
Preserving the Pump
Pre-Conditions:
Pump has been demounted.
Ö Chap. "9.1 Demounting the Pump", Page 55
Pump is clean and dry.
All openings are closed using flange covers or caps.
Procedure:
1. Apply corrosion preventative (Castrol SafeCoat DW 18X) evenly to the
pump's exterior surface.
2. Allow the pump to dry.
The pump should only be preserved on the exterior.
WARNING Damage to Property!
Improper preservation or no preservation at all may cause
corrosion to the pump.
If required, properly preserve the pump
Ö Chap. " Preservation Conditions", Page 31
Before the initial set-up of the pump, it does not need to be de-preserved.