A SERVICE OF

logo

KM0832 User Manual
26
(Continued from previous page.)
2. If you wish to install any console modules or KVM adapter cables on the
KM0432 or KM0216, follow the procedures described in Grounding,
page 15.
(Repeat the above steps for any additional KM0432 or KM0216 you wish
to add to the chain.)
3. Plug the power cords into an AC power source and into the power sockets
on the KM0832 and KM0432 or KM0216.
4. Power on the installation according to the following procedure:
a) Power on the first-level KVM switch (KM0832). Wait one minute for
the KVM switch to ascertain its position. (The KM0832 does not have a
station ID because it always occupies the first station position.)
b) Power on each KVM switch on the installation in turn (second station,
then third station, etc.). In each case, wait for the position to be
ascertained and displayed on the current station ID before powering on
the next station. (The ID for the second-level KVM switch is 02, the ID
for the third-level KVM switch is 03, etc.)
c) After all the KVM switches are powered on, power on the computers.