Toshiba LF410/LF600 Oxygen Equipment User Manual


 
LF410/LF600 LF410/LF602
7
Unit : mm
88
40
(126)
(35) 91
R(PT)½ Male Screw (Two places)
(L2)
Φ66
87
L1
Note1: Cable glands are not provided for LF414 of FM
and CSA approved type.
Refer to the part Cable connection port at detector.
Note2: 1 inch = 25.4mm
BS16, DIN PN16 and JIS 10K dimensions:
Meter size
(mm)
L1
(mm)
L2
(mm)
D1
(mm)
Weight
(kg)
25 80 168 66 approx. 3
ANSI class 150 and class 300 dimensions:
Meter size
(inch)
L1
(inch)
L2
(inch)
D1
(inch)
Weight
(lb)
1 3.15 6.61 2.60 approx. 7
Figure 7. Separate type detectors
LF410 and LF414
Meter size 25mm (1")
The dimension of L1 is changed when the material of
grounding ring is chosen Pt-Ir or Ta
Meter size L1
15mm (1/2”) 77mm (3.03 inch)
25mm (1”) 95mm (3.74 inch)
40mm (1 1/2”) 115mm (4.53 inch)
50mm (2”) 126mm (4.96 inch)
80mm (3”) 126mm (4.96 inch)
100mm (4”) 136mm (5.35 inch)
150mm (6”) 242mm (9.53 inch)
200mm (8”) 312mm (12.28 inch)
Unit : mm
88
40
(126)
(35)
91
R(PT)½Male Screw (Two places)
(L2)
L1
ΦD1
Note1: Cable glands are not provided for LF414 of FM
and CSA approved type.
Refer to the part of Cable connection port at
detector.
Note2: Eye bolts are provided at the top for flowmeters
sized 200mm (8").
Note3: 1 inch = 25.4mm
BS16, DIN PN16 and JIS 10K dimensions:
Meter size
(mm)
L1
(mm)
L2
(mm)
D1
(mm)
Weight
(kg)
40 100 190 85 approx. 4
50 110 207 102 approx. 5
80 110* 232 127 approx. 6
100 120* 264 159 approx. 9
150 230 324 216 approx. 21
200 300 385 267 approx. 35
ANSI class 150 and class 300 dimensions:
Meter size
(inch)
L1
(inch)
L2
(inch)
D1
(inch)
Weight
(lbs)
1-1/2 3.94 7.48 3.35 approx. 9
2 4.33 8.15 4.02 approx. 11
3 4.33* 9.13 5.00 approx. 13
4 4.72* 10.39 6.26 approx. 20
6 9.06 12.76 8.50 approx. 47
8 11.81 15.16 10.51 approx. 78
* When Teflon PFA lining is selected, L1 in the table
above becomes as follows:
L1: 115mm (4.53 inch) for meter size 80mm (3")
L1: 126mm (4.96 inch) for meter size 100mm (4")
Figure 8. Separate type detectors
LF410 and LF414
Meter size 40 (1 1/2") to 200mm (8")