Toshiba H-9100 Scale User Manual


 
10. PROGRAMMING PROCEDURES
10.15 LON SYSTEM
10-25
Data Transmission
The following data are down-line-loaded.
Page 1: (0). All (PLU+ING+NUTRI) Page 2: (0). SPEED KEY
(1). PLU (1). LOGO
(2). ING. (2). VENDOR
(3). NUTRITION (3). FREE FORMAT
(4). U. PRICE (4). ADDRESS
(5). DATE/TIME (5). INITIAL
(6). MESSAGE LINK (Message) (9). CHANGE PAGE
(7). LOCK SCALE (Check the LON cable)
(8). OPEN SCALE (Release the lock after checking the LON cable.)
(9). CHANGE PAGE
Select a DLL data
using the
and keys.
Release the scale from the error.
0: CANCEL
1: RETRY
2: CONTINUE
ENTER
p
NOTE: DLL is performed automatically in the following two ways. It is selectable by the Initial
Settings #0-6 and #0-7.
(1) LOCK SCALE method
Step 1: LOCK SCALE is sent. (*1)
Step 2: Selected data is sent. (*2)
Step 3: OPEN SCALE is sent.
*1: If an error occurs during step 1, the error terminal ID# is indicated.
Select cancel, “retry” or continue to release the terminal from an
error.
cancel: Quits the operation after sending OPEN SCALE
retry: Tries to send LOCK SCALE again.
continue: Ignores the error terminal and starts DLL.
*2: If an error occurs during step 2, the error terminal ID# is indicated.
Press the key to return to the DLL data selection menu.
(2) Background DLL
Step 1: Selected data is sent. (*3)
*3: If an error occurs, the error terminal ID# is indicated. Press the
key to return to the DLL data selection menu.
CLEAR
CLEAR
NEXT PLU
-
n