11-28
11. PROGRAMMING PROCEDURES
11.16 TRANSFERRING LOGO DATA
11.16 TRANSFERRING LOGO DATA
In ESB Limited Spec. Mode, this programming is unavailable.
Menu Group: 2
Item No.:8
Logo data is created on a PC and stored into RAM through the CMT interface. Two different sizes of
logos, 320x118 dots and 256x64 dots, are available on the SL-9000 series. 64KB of RAM area is secured
for logo data, in which the maximum of 13 logos (320x118 dots) or 26 logos (256x64 dots) can be stored.
Before starting the following operation, set the initial setting #10-7 to 1.
<MENU>
Group 2
ENTER
8
ESC.
PROG.
<MENU>
Group 2
Main
<MENU>
Load the tape into
the CMT Loader
Select a transmission item.
1: SAVE(SL-9000 CMT)
2:VERIFY(SL-9000=CMT)
3:LOAD(SL-9000 CMT)
320x118-dot size logo
The logo is printed at the lower
center of the print area.
NOTE: Two sizes of logos are printed differently as follows:
Table 6: Error message during data transmission
Error message
Cause
Error position
Header text Data text
TIME OUT ERROR
DATA ERROR
Timeout
Incorrect segment
Incorrect logo size
Incorrect number of logos
Incorrect logo number
Incorrect number of dots to be printed.
Parity error
Framing error
Overrun error
256x64-dot size logo
<Label> <Receipt>
A whole Logo #1 and a half of
logo #2 area printed.
: Print area for logo : Logo