PROGRAM INSTRUCTIONS (cont)
2. Depress MODE (S1) switch once.
The text
 followed by the current value of Alarm Set Point High
1 (SPH1) will be displayed. Use S2 and S3 to set Alarm Set Point
High 1 to the desired value. Proceed to Step 3 to set Alarm Setpoint
Low 1 (SPL1) or depress S4 to exit MODE sequence. If S4 is
depressed, the new value for SPH1 will be saved in non-volatile
NOVRAM memory.
3. Depress MODE (S1) switch once.
The text  followed by the current value of Alarm Set Point Low
1 will be displayed. Repeat Step 2 to set Alarm Set Point Low 1 to
the desired value. Proceed to Step 4 or depress S4 to exit.
4. Depress MODE (S1) switch once.
The text
 followed by the current value of Alarm Set Point High
2 will be displayed. Repeat Step 2 to set Alarm Set Point High 2 to
the desired value. Proceed to Step 5 or depress S4 to exit.
5. Depress MODE (S1) switch once.
The text  followed by the current value of Alarm Set Point Low
2 will be displayed. Repeat Step 2 to set Alarm Set Point Low 2 to
the desired value. Proceed to Step 6 or depress S4 to exit.
6. Depress MODE (S1) switch once.
The text
 followed by the current value of Alarm Hysteresis High
will display. Repeat Step 2 to set Hysteresis High to the desired
value. The maximum value for HH is 99 counts. Proceed to Step
7 or depress S4 to exit.