*1 One CPU module can control the following number of modules by setting CC-Link network parameters.
• Q00UCPU or Q01UCPU: Up to 2 modules
• Q02UCPU: Up to 4 modules
• Other CPU modules: Up to 8 modules
There is no restriction on the number of mounted modules when the parameters are set with the CC-Link dedicated
instructions.
*2 For the applicable GOT models, refer to the connection manual for the GOT used.
*3 The number indicates interrupt modules with no interrupt pointer setting. With interrupt pointer setting, no restriction
applies.
*4 When one of the following CPU modules is used in the multiple CPU system, the number of modules can be mounted is
restricted to two.
• High Performance model QCPU
• Process CPU
*5 Modules of function version B or later can be mounted.
*6 One CPU module can control the following number of modules by setting CC-Link IE Field Network parameters using a
programming tool.
• Q00UCPU or Q01UCPU: Up to 2 modules
• Q02UCPU: Up to 4 modules
• Other CPU modules: Up to 8 modules
There is no restriction on the number of mounted modules when the parameters are set with the CC-Link IE Field
Network dedicated instructions.
*7 The number of mountable modules is restricted when a high-speed input module is used as an interrupt module by
turning off the function switch (SW2).
*8 The module can be used when a Universal model QCPU with a serial number (first five digits) of "13102" or later is set to
a control module. However, it cannot be used if a process CPU is used in combination. ( Page 188, Appendix 3)
*9 With a High-speed Universal model QCPU, only high-speed data logger modules with a serial number (first five digits)
"14122" or later can be used.
Remark
For the restrictions on mounting A-series modules on the QA6B or QA6ADP+A5B/A6B, refer to the following.
QA65B/QA68B Extension Base Unit User's Manual
QA6ADP QA Conversion Adapter Module User's Manual
For the restrictions on mounting AnS-series modules on the QA1S6ADP+A1S5B/A1S6B, refer to the following.
QA1S6ADP Q-AnS Base Unit Conversion Adapter User's Manual
QA1S6ADP-S1 Q-AnS Base Unit Conversion Adapter User's Manual