Accuracy:
Pressure …………………… +/- 3 mmHg
(+/- 0.4 kPa)
Pulse ……………………… +/- 5%
Power supply ……………… 3V DC, 2 LR03 / AAA /
UM4-size 1.5V batteries
Power save ………………… Auto power off after 1
minute of non-activity
Operating environment:
Operation ………………… 50°F to 104°F
(10°C to 40°C)
Storage / Transport ………… -4°F to 140°F
(-20°C to 60°C)
Humidity range …………… 10% to 83% relative
humidity
Limited Two-Year Warranty
Lumiscope guarantees this product free from defects in material and
workmanship for a period of two years from the date of purchase,
except as noted below:
This Lumiscope product warranty does not cover damage caused
by misuse or abuse, the attachment of any unauthorized accessory,
alteration to the product, or any other conditions whatsoever that
are beyond the control of Lumiscope. Lumiscope shall not be
responsible for any type of incidental, consequential, or special
damage. All implied warranties, including, but not limited to those
implied warranties of fitness and merchantability, are limited to the
total duration of two years from the original date of purchase.
To obtain warranty service on your Lumiscope Blood
Pressure Monitor, please contact the Lumiscope Repair Department
at 1-800-672-8293 or visit www.lumiscope.net. There is a $15 fee
for return shipping and handling. Please make checks payable to
The Lumiscope Co., Inc.
Upon receipt, Lumiscope will repair or replace, as appropriate, this
blood pressure monitor and return it to you. Warranty is solely
through the Lumiscope Repair Department. Service of this product
by anyone other
than the Lumiscope Repair Department voids
warranty.
In the event that Lumiscope does not abide by the terms of this
warranty, the consumer may seek breach of contract remedies in
the New York State Federal courts
of law. This warranty gives you
specific legal rights and you may also have other rights which vary
from state to state.
Some states do not allow the exclusion or limitation of incidental
or consequential damages, so the above limitation may not apply
to you.
15
Problem Symptom Check This Remedy
No user
memory
Cannot find
a record
The memory
was not saved
after taking a
measurement
Retake the
measurement.
Press or
to save
the corresponding
user’s memory
The record was
stored to the
wrong user
memory
Press to
view User 1’s
record. Press
to view
User 2’s record
Technical Specifications
Measuring method ………… Oscillometric
Measurement location .….….Wrist
Memory …………………… 60 records per user
Maximum number of users … 2
Dimensions ……………… 3.5 x 3.4 x 1.2 inches
(90 x 86 x 30.8 mm)
Weight …………………… 6.3 oz (180g) without
batteries
Cuff circumference ………… 5.3 to 7.7 inches (13.5 to
19.5 cm)
Measuring range:
Pressure ………………… 30 to 280 mmHg (4.0 to
37.3 kPa)
Pulse ……………………… 40 to 200 pulse/min