IEEE 1547 (Default)
Parameter Range Clearing Time (s)
Phase Voltage V < 60V <0.16
Voltage
60V ≤ V < 106V < 2.00
132 ≤ V < 144V < 1.00
V ≥ 144V < 0.16 (< 0.016, Hawaii mode - TOV)
1)
Frequency
> 60.5Hz < 0.16
< 59.3Hz (< 57 Hz,
Hawaii mode)
1)
< 0.16
Note 1 : This test is performed in nominal conditions, except for test parameter
Note 2 : After clearing, if grid returns to the normal state, it takes up to 5 minutes for operation of AC module
Response to Abnormal Conditions
Dedicated Cables
Trunk
Cable
Type TC-ER sunlight resistant
Max. Voltage 600V
Max. Current 20A
Size 12AWG
Connector
Max. Voltage 300V
Max. Current 20A
Drop
Cable
Type TC-ER sunlight resistant
Max. Voltage 600V
Max. Current 5A
Size 18AWG
Connector
Max. Voltage 300V
Max. Current 5A
Certication
UL9703, UL6703A
Dimensions
400 mm
(95.75 inch)
53 mm
(2.09 inch)
122 mm
(4.80 inch)
1,200 mm
(47.24 inch)
66 mm
(2.60 inch)
31.5 mm
(1.24 inch)