Kohler K-1221-AC Bathroom Aids User Manual


 
19
106548-CA (9437)
Kohler Co., Kohler WI
E. FIELD WIRING CONTROL BOX
COMPARTMENT - 230 V, 50 HZ
WARNING: Risk of electrical shock. Make sure
the power has been disconnected before
performing the following procedures. Refer to
Important Safety Instructions located on page 2.
CAUTION: Risk of electrical shock. All services
must have an Earth Leakage Circuit Breaker
(ELCB) which will provide additional protection
against line-to-ground shock hazard. A separate
service is required for the whirlpool.
The whirlpool controls and system have been prewired
at the factory. A licensed electrician should make a
routine service connection to the field wiring
compartment of the control box containing blue and
brown wires and earth lug.
* For bonding in accordance with National and Local
Codes.
Field Wiring
Compartment
Bonding
(Earthing) Lug*
Air
Actuator
Air
Actuator
Tube
Pump
Control
Box
F. CONNECT CONTROL BOX - 230 V, 50 HZ
Connect service to the field wiring compartment of the
control box. The 50 Hz model control box contains blue
and brown wires and earth lug.
A 230 V, 15 A, 50 Hz dedicated circuit is required.
Provide an Earth Leakage Circuit Breaker.
Provide a separate equipment earthing conductor for the
inside earth lug. The earthing conductor must not be
connected to any current carrying conductor. Follow
local electrical codes. A 230 V, 15A, 50 Hz separate
circuit is required.
Earth
(Ground) Lug
Earth
(Ground)
Neutral
Earthing Lug (for
bonding in accor-
dance with national
and local codes)
Blue
(Neutral)
Brown
(Phase)
Wire Connectors
Phase (Line)