Kohler K-1221-AC Bathroom Aids User Manual


 
17
106548-CA (9437)
Kohler Co., Kohler WI
12. ELECTRICAL CONNECTIONS - AIR ACTUATOR VERSIONS
A. IDENTIFY ELECTRICAL REQUIREMENTS
The model number is printed on a plate at the pump end
of the module.
The model number identifies electrical rating. Electrical
connections for each model vary.
S K-1201-AC, K-1206-AC, K-1211-AC,
K-1216-AC, K-1221-AC: 60 Hz
(Follow Step B. below.)
S K-1201-J1-AA, K-1201-J1-AB, K-1206-J1-AA,
K-1206-J1-AB, K-1211-J1-AA, K-1211-J1-AB,
K-1216-J1-AA, K-1221-J1-AA: 60 Hz
(Follow Steps C. and D. below.)
S K-1201-JA-AA, K-1206-JA-AA, K-1211-JA-AA,
K-1216-JA-AA, K-1221-JA-AA: 50 Hz
(Follow Steps E. and F. below.)
See Electrical Requirements section on page 11 of
Product Requirements.
B. WIRING INFORMATION - 120 V, 60 HZ
(EXCLUDING -J1 MODELS)
WARNING: Risk of electrical shock. To reduce
the risk of electric shock, connect only to a properly
grounded, grounding-type receptacle, protected
by a Ground-Fault Circuit-Interrupter (GFCI). Do
not remove the plug’s grounding pin. Do not use a
grounding adapter.
Your Kohler Whirlpool bath is equipped with a cord and
plug. All wiring of the pump and control has been
completed at the factory. A licensed electrician must
install a GFCI protected, 120 Volt, 15 Amp, grounded
outlet. Your whirlpool may then be plugged into this
outlet. No other load should be on this circuit. Locate the
outlet within reach of the 36” cord.