Harmar Mobility RPL400 Personal Lift User Manual


 
Manual Override
Your lift is equipped with a manual handcrank, to be used in the case of a power failure.
Step 1
Before using the manual handcrank verify
that it’s use is required. Check that the
emergency stop switch is pulled out. Check
that the electrical cord is plugged into the
wall. Also check that the buildings circuit
breaker has not tripped. Try to run the lift by
pushing both the up and down buttons. If the
lift still will not run, complete the following
steps:
Step 2
Unplug the lift from the wall.
Warning: Do not service or operate the
manual handcrank while the lift is
connected to electricity.
Step 3
Remove the screws and remove the top cap
at the top of the tower.
Step 4
Insert the manual handcrank into the
opening on the top of the brake assembly. It
may be neccesary to slightly rotate the
handcrank until it fully seats down on the hex
portion of the brake. Rotate the crank to
raise or lower the platform.
Warning: Never operate the lift while the
manual override crank is inserted into the
lift.
13