Harmar Mobility RPL400 Personal Lift User Manual


 
Setting the Limit Switches
Your lift is equipped with upper and lower limit switches. The vertical location of these switches may be
adjusted to fit your application.
Typically the upper limit switch will need to be adjusted so the platform will stop level with the upper
landing. The lower limit will typically not need adjusting.
Step 1
Verify the emergency switch is in the ON
position. Run the lift in the up direction until
the platform floor is level with the upper
landing.
1A Unplug the lift’s power cord from the wall
before going to the next step (AC units).
1B Uplug the power cable from the battery
box before going to the next step (DC units).
Warning: Moving components can cut
and crush. Do not operate the lift if you
are in close proximity to any drive
components. Be aware that loose
clothing or jewelry may catch on moving
parts.
Step 2
Remove the screws at the top of the lift that
attach the front cover.
Step 3
Remove the front cover by tilting it forward
and lifting upwards. The bottom of the front
cover sets on a pin on either side of the lift
frame. Set the cover aside in a safe location
where it will not get damaged.