Harmar Mobility CPL1000 Personal Lift User Manual


 
EMI and Flush Strike Interlocks (optional)
The optional EMI or Flush Strike Interlocks are
provided with a combination mechanical lock and
electric contact. They are to be used with existing
doors.
The interlock:
Prevents the lift from running if the door is
not closed.
Prevents the door from being opened if the
platform is not at the landing.
Unlocks when the lift is on the landing limit
switch.
Flush Strike Interlock
Refer to the instructions inside the strike box for
mounting requirements.
EMI Interlock
1) Position interlock to door jamb and mark
mounting holes.
2) Fasten Interlock to door jamb with #8 wood
screws.
3) Route 4-conductor Interlock cable thru hole in
top of interlock and make wire connections.
4) Attach door keeper and emergency key plates
to hoistway door.
.
14
Alengthofmulticonductorwirewillneedtoberan
fromthebottomofthelifttowertotheinterlocks.
Consultlocalcodesfortypeandmounting
requirements.Afterwiringiscompleted,thewiring
harnessmustbepluggedintoitappropriate
receptacleonthecontroller(refpg5).
WiringConnections
FlushStrike
LiftHarness
Yellow/*Black Black
Yellow/*Purple Green
White White
Orange Orange
Blue Blue
Brown Brown
*ColorswhenusedonaDC(battery)
poweredliftoption.
EMI
 LiftHarness
Black(A) Black
Black(B) Green
Yellow(C) White
Yellow(D) Orange
N/A *Blue
N/A *Brown
*MustbetiedtogetherwhenusinganEMI
Interlock.