3. Name of Each Part
N-type
P-type
4. Instructions classified by Power Source
1. Adapter
- Connect the adapter (DC 12V, 300mA) with the power cord. Connect the jack to the adapter jack in the back side of scale body.
- Use only authorized adapter. Using a different adapter may cause a problem to the scale.
- When connecting adapter while the battery is in the scale, the battery power will be automatically turned off and adapter power will be charged even though the battery is in
the scale.
2. Battery (D-size)
- Open the battery cover. Place 6 units of batteries to polarity at the bottom of the scale. Close the cover properly.
- Exchange the battery when “BAT” is indicated in the display.
- Not available to accurately weigh during “BAT” state.
- Use same kinds of batteries when using batteries. Using different batteries may cause a problem to the scale.
3. Rechargeable battery
- Put the rechargeable battery pack into the bottom of the scale after opening the battery cover.
- Put the 2 pin connector from rechargeable battery pack into the power pack.
- Must connect adapter jack directly from the pack case or connect adapter jack to its power pack to charge.