Escali E30CBB Scale User Manual


 
Procedures to set up time to automatically turn off the power
- Push the “C” key for 5 seconds while the weight, quantity, unit weight of the scale are zero state and Tare is released as the picture No. 1.
Weighing range : 40 g ~ 6/15 kg, e = d : 2 g / 5 g
(0.1 lb ~ 15/30 lb, e = d : 0.005 lb/0.01 lb)
lb
Model : CB-15N
WEIGHT
UNIT WEIGHT
QUANTI TY
BAT
Short
Uni t Wt .
TOTAL
TARE
ZERO
Sho rt
Q' t y
kg
g/pc
pcs
- Set up the preferable time to turn off the power by using the “+” key or “=” key while the display is showing as picture No. 2.
Weighing range : 40 g ~ 6/15 kg, e = d : 2 g / 5 g
(0.1 lb ~ 15/30 lb, e = d : 0.005 lb/0.01 lb)
lb
Model : CB-15N
WEIGHT
UNIT WEIGHT
QUANTI TY
BAT
Short
Uni t Wt .
TOTAL
TARE
ZERO
Sho rt
Q' t y
kg
g/pc
pcs
- Complete the procedures to set up the time using the “M” key. Not pushing the “M” key does not save this function.
z The scale is automatically turned off when not being used for selected time without inputting a key or changing the weight.
z Used in order to prevent unnecessary consumption of the battery.
z Select time to automatically turn off the power as OFF – 5min.- 10min. – 30min. – 60min. – 120min.
z Release the time setup by setting up with ‘OFF’.
z Without inputting a key for 5 seconds will automatically set back to the scale mode in the picture No. 2.
z The scale is dispatched with ‘5 minutes automatic turning off the power’ mode. (The scale is automatically turned off when not being used for 5 minutes.)
7. Error Indication and its Information
Error Information Solution Error Information Solution
Err-01 Memory reading error A/S Err-02 Zero range error (Test mode) A/S
Err-03 Problems in Weighing range (Test mode) A/S Err-d0 Exceed maximum weight Check the platform, A/S
Err-d1 Below minimum weight Check the platform Err-d2 Problems in AD converter A/S
Err-d3 Tare range error: Unstable condition, Exceed
tare range, Setting up the Tare during “-
(minus)“ weighing
Check the scale Err-d4 Exceed maximum data range of AD
converter
Check to see if there is anything
on the platform, A/S
Err-d5 Below minimum data range of AD converter Check the platform, A/S Err-d6 Weighing range error A/S
Err-d7 Problems in Zero / Exceed the range A/S Err-d8 Not in a stabilized condition The scale is experiencing
vibrations or wind currents : Place
the scale in a stabilized condition
- When the scale stops operating or ON/OFF key does not operate
- Reset the battery or adapter jack. When they do not operate after resetting the battery or adapter jack, claim the after service.