Product Certifications
European Directive Information
A copy of the EC Declaration of Conformity can be found at the end of the Quick
Start Guide. The most recent revision of the EC Declaration of Conformity can be
found at www.rosemount.com.
Ordinary Location Certification from FM Approvals
As standard, the transmitter has been examined and tested to determine that the
design meets the basic electrical, mechanical, and fire protection requirements
by FM Approvals, a nationally recognized test laboratory (NRTL) as accredited by
the Federal Occupational Safety and Health Administration (OSHA).
North America
E5 USA Explosionproof (XP) and Dust-Ignitionproof (DIP)
Certificate: 0T2H0.AE
Standards: FM Class 3600 - 2011, FM Class 3615 - 2006, FM Class 3810 - 2005,
ANSI/NEMA 250 - 2003
Markings: XP CL I, DIV 1, GP B, C, D; DIP CL II, DIV 1, GP E, F, G; CL III;
T5(-50 °C T
a
+85 °C); Factory Sealed; Type 4X
I5 USA Intrinsic Safety (IS) and Nonincendive (NI)
Certificate: 1Q4A4.AX
Standards: FM Class 3600 - 2011, FM Class 3610 - 2010, FM Class 3611 - 2004,
FM Class 3810 - 2005
Markings: IS CL I, DIV 1, GP A, B, C, D; CL II, DIV 1, GP E, F, G; Class III; DIV 1 when
connected per Rosemount drawing 03031-1019; NI CL 1, DIV 2, GP A, B, C,
D; T4(-50 °C T
a
+70 °C), T5(-50 °C T
a
+40 °C) [HART]; Type 4x
Special Conditions for Safe Use (X):
1. The Model 3051 transmitter housing contains aluminum and is considered a
potential risk of ignition by impact or friction. Care must be taken into account
during installation and use to prevent impact and friction.
2. The Model 3051 transmitter with the transient terminal block (Option code T1) will
not pass the 500 Vrms dielectric strength test and this must be taken into account
during installation.
C6 CSA Explosionproof, Dust-Ignitionproof, Intrinsic Safety and Division 2
Certificate: 1053834
Standards: ANSI/ISA 12.27.01-2003, CSA Std. C22.2 No. 30 -M1986,
CSA Std. C22.2 No.142-M1987, CSA Std. C22.2. No.157-92, CSA Std. C22.2
No. 213 - M1987
Markings: Explosionproof for Class I, Division 1, Groups B, C and D; Suitable for Class I,
Zone 1, Group IIB+H2, T5; Dust-Ignitionproof Class II, Division 1, Groups E, F,
G; Class III Division 1; Intrinsically Safe Class I, Division 1 Groups A, B, C, D
when connected in accordance with Rosemount drawing 03031-1024,
Temperature Code T3C; Suitable for Class I, Zone 0; Class I Division 2 Groups
A, B, C and D, T5; Suitable for Class I Zone 2, Group IIC; Type 4X; Factory
Sealed; Single Seal (See drawing 03031-1053)