E&J GF0600059REVB06 Wheelchair User Manual


 
Metro Power III Owner’s Manual GF0600059RevB06, November 2006
23
ON/OFF switch
e ON/OFF switch turns battery charger power on and off.
AC voltage switch
e AC voltage switch changes the voltage between 115 volts and 230 volts. See Battery voltage
switch on wrong setting in TROUBLESHOOTING for directions on switching voltage.
AC fuse compartment
e AC fuse compartment houses the AC fuse and a spare. See Check / replace the AC fuse in
TROUBLESHOOTING for directions on changing the AC fuse.
Line connector
e line connector can be removed to access the AC fuse compartment.
AC connector
e AC connector plugs into the power outlet to charge the batteries.
BATTERY CHARGER FRONT PANEL
FUSE
output
connector
red LED
charge indicator
(yellow & green) LED
output fuse
front
panel
Output connector
e output connector plugs into the wheelchair battery charger receptacle to charge the batteries.
Red LED
e red LED shows power on (battery charger plugged into power outlet and ON/OFF switch
turned on).
Charge indicator (yellow & green) LED
e charge indicator LED illuminates yellow when charging, and changes to green when the batter-
ies are fully charged. e charge indicator LED may flicker between green and yellow before finally
turning green, especially when charging older batteries.
Output fuse
See Check / replace the output fuse in TROUBLESHOOTING for directions on changing the
output fuse.