Set the high temperature limit stop (optional)
Turn the water on to the tub spout or handshower. Use a 3 mm Allen wrench to loosen the
handle screw. Remove the handle from the valve.
Carefully remove the retainer clip and the limit stop ring (1).
Turn the temperature control stem until the water is the desired high temperature, usually
110°F* (2). Turning the stem clockwise will make the water cooler, turning it counter-clock-
wise will make the water warmer.
Install the stop ring so that it is against the stop -- you should not be able to turn the stem
further counter-clockwise. Install the retainer clip (3).
Install the handle. Tighten the screw. Justify the handle.
*Know and follow all applicble local plumbing codes when setting the high temperature limit stop. In Massachusetts,
the maximum output temperature can be no higher than 112° F.
Hold the handle lever in one hand.
With the other hand, turn the tempera-
ture control knob until the 100° mark is
next to the indexing mark on the handle.
Install the handle on the valve. Tighten
the screw.
1 2