Axor 6405000 Thermometer User Manual


 
3
04198XX0
04172XX0 04185XX0
Technical Specification
Recommended pressure 45 - 72 psi
Maximum hot water temp. 165° F*
Recommended hot water temp. 120° - 140° F*
Flow rate @ 44 PSI 8 gpm
Safety stop 100° F
1/2" female NPT inlets
Maximum mounting surface thickness 1 3/8"
Hole size in mounting surface 2 3/8"
*Know and follow all applicable local plumbing codes when setting the temperature on the water heater.
Installation Considerations
For best results, Hansgrohe recommends that this unit be installed by a licensed, profes-
sional plumber.
Please read over these instructions thoroughly before beginning installation. Make sure
that you have all tools and supplies needed to complete the installation.
The mounting surface must be installed and made watertight prior to installation.
For best service of the ThermoBalance valve, the pressure of the incoming hot water and
the pressure of the incoming cold water must be equal.
This valve is for a two-function installation. Both outlets must be plumbed. If only one
function is to be used, loop the two outlets together. Do not plug either outlet.
Some areas have plumbing codes limiting the maximum output temperature. The high
temperature limit stop may be reset to comply with these codes. See page 7.