Axor 6405000 Thermometer User Manual


 
6
Install the valve trim
Remove the plaster shield.
Push the escutcheon over the valve.
Install the handle. Tighten the screw with a 3 mm
Allen wrench. The screw must engage the slot on the
cartridge.
Justify the handle.
Set the high temperature limit
stop, if required.
Justify the handle
Turn the water on to the tub spout or hand-
shower. Place a thermometer in the water
stream. Turn the temperature control knob until
the output water temperature is 100°F. Turn the
water off.
Loosen the handle screw with a 3 mm Allen
wrench. Remove the handle.