![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/2/f0/2f00f4c0-5503-476b-a441-97110614d866/2f00f4c0-5503-476b-a441-97110614d866-bgc2.png)
Error Messages 195
D24—Owner’s Manual
FS DIFFER
Recording is not possible because
the sampling rate of the selected
project is not the same as the cur-
rent D24 setting.
Set the sampling rate on the D24 to
match that of the project. See “Selecting
a Wordclock Source” on page 124 for
more information.
RECCH NOTSEL
No tracks are selected for record-
ing.
Select a track for recording. See “Record-
ing” on page 33 for more information.
MO PROTECT
The disk is write protected.
Turn off the write protection. See “Write
Protecting Disks” on page 24 for more
information.
PROJ PROTECT
The project is write protected.
Turn off the write protection. See “Pro-
tecting Projects” on page 82 for more
information.
DATA FULL
There is no space available for
storing project management files.
Retrieve some disk space by using the
Optimize function. See “Recovering Disk
Space” on page 172 for more informa-
tion.
Delete or erase an unwanted project.
Message Meaning Remedy