![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/6/10/61065817-f671-4dd4-83f4-dbc5c763ed72/61065817-f671-4dd4-83f4-dbc5c763ed72-bg41.png)
Installation Planning Guide 6-1
6. Printer requirements and
specifications
This chapter provides power and space requirements for the
DocuPrint 100/115/135/155/180 EPS printer. It also provides
printer environmental specifications.
For information about controller power and space requirements,
refer to the “Controller specifications and requirements” chapter
of this guide.
Power requirements
Your printer has important power requirements that must be
accommodated. These requirements are summarized in the
table below.
For further details on power requirements, refer to the voltage
charts and wiring diagrams that follow.
For details on controller power requirements, refer to the
“Controller specifications and requirements” chapter of this
guide.
Agency certification: UL 478 and 1950, IEC 950, CE Mark,
CSA 22.2 #220-1986, FCC (Class A), and VDE 0871 (Class A).
Table 6-1. Printer electrical requirements
Component Voltage Amp. service
KVA rating
(operating mode)
Additional
Requirements
Printer 60 Hz
(U.S. and
Canada)
120/240 VAC or 120/208
VAC (Cord 1)
120/240 VAC or 120/208
VAC (Cord 2 for DP 155
and DP180 only)
50 amp (Cord 1)
30 amp (Cord 2
for DP 155 and
DP180 only)
Operating: 7.3
+ .75 per middle
module stacker
14-50R (Cord 1)
14-30R (Cord 2
for DP 155 and
DP180 only)
Printer 50 Hz -
WYE (Star)
380, 400, 415 VAC
(3 phase, 5 wire)
30 amp Consult local
service
representative