A SERVICE OF

logo

– 12 –
13. Set both timer dials to 2 minutes. The green ready lights will go off, the red cooking lights will
come on and steam will be heard entering the compartments.
14. Wait until 1 minute is left on the timers.
15. Open each door and observe that steam has stopped entering into each compartment. The
red cooking lights remain on.
16. Close the compartment doors. Steam generation and timers resume. Make sure that steam
from the drain is being cooled by water from the cold water condenser.
17. When the timer dials are at 0 minutes, each buzzer will sound. Steam flow to the
compartments will stop. The red cooking lights will go off. The green ready lights will come
on.
18. Turn timer dials to the OFF position to silence the buzzers.
19. Press [ O ] on the power switch on the boiler (Fig. 2) to turn the steamer off. The indicator
lights are not lit. The boiler will automatically blow down.