A SERVICE OF

logo

MAINTENANCE AND TROUBLE-SHOOTING
" Jlost treadmill problems can be solved by following the simple steps below. Find the symptom that
applies, and follow the steps listed, ff further assistance is needed, call our toll-free HELPUNE at
1-800-736-6879, Monday through Saturday, 7 a.m. until 7 p.m. Central Time (excluding holidays).
1. SYMPTOM: THE POWER DOES NOT TURN ON
a. Make sure thatthe power cord is plugged intoa surge suppressor, and that the surge suppressoris plugged
intoa prepedy groundedoutlet (see page 7). Use only a single-outlet surge suppressorthat is UL 1449
listedas a transient voltage surge suppressor (TVSS). The surge suppressor must have a UL suppressed
voltage rating of400 volts or less and a minimumsurge dissipation of 450 joules. The surge suppressor
must be electricallyrated for 120 volts AC and 15 amps.
b. After the power cordhas been plugged in, make sure that the key isinserted intothe console as far as itwill
go. See step 1 on page 9.
c. Check the circuitbreaker located on the treadmill near the
power cord. If the switchprotrudes as shown, the circuit
breaker has tripped. To reset the circuit breaker, wait for five
minutes and then press the switch back in.
d. Check the on/off switch located on the treadmillnear the
power cord. The switchmust be in the on position.
c
Tdpped
0 j
On
Position
2. SYMPTOM: THE POWER TURNS OFF DURING USE
a. Check the circuitbreaker located on the treadmillframe near the power cord (see 1. c. above). If thecircuit
breaker has tripped,wait for five minutesand then press the switch back in.
b. Make sure that the power cord is plugged in.
c. Remove the key from the console. Reinsert the key fully intothe console. See step 1 on page 9.
d. Make sure that the on/off switch is in the on position.
e. If the treadmill still will not run, please call ourtoll-free HELPLINE.
3. SYMPTOM: THE PULSE SENSOR DOES NOT FUNCTION PROPERLY
a. Make sure to stand on the foot rails and avoid moving your hands while measuring your heart rate.
Excessive movement may interferewith hear[ rate readings. If the pulse sensor is not used correctly,your
heart rate willnot be shown.
b. Do not hold the metal contacts too tightly; doing so may interfere with heart rate readings.
c. For the most accurate heart rate reading, hold the contacts for about 15 seconds.
d. For optimal performance of the pulse sensor, keep the contacts clean. The contacts can be cleaned with a
soft cloth--never use alcohol, abrasives, or chemicals.
17