72 C3412M (9/06)
ACK ACTION
Acknowledge action programs the alert label behavior after the alert condition has been
acknowledged. The following settings are available for acknowlegde:
ALWAYS ON The alert label is displayed until alert conditions are cleared.
OFF 8 HRS The alert label is turned off for 8 hours. Label returns after 8 hours if the alert
condition persists.
OFF 24 HRS The alert label is turned off for 24 hours. Label returns after 24 hours if the alert
condition persists.
OFF 48 HRS The alert label is turned off for 48 hours. Label returns after 48 hours if the alert
condition persists.
ACTIVATE AUX
This setting activates an auxiliary when an alert condition exists. Settings include the following:
NONE (default) Not activated.
1 An alert condition will close AUX 1.
2 An alert condition will close AUX 2.
CURRENT READING
The Current Reading menu displays the existing status of temperature, pressure, and dew point
inside the dome system. An arrow displayed to the left of a menu item denotes that an alert
condition exists.
An up arrow indicates the reading is over the threshold. A down arrow indicates the reading is
below the threshold.
The high temperature alert occurs if the temperature is above 140°F (60°C).
The low temperature alert occurs if the temperature is below -40°F (-40°C).
The high pressure alert occurs if the pressure is above 13 PSIG.
The low pressure alert occurs if the pressure is below 1 PSIG.
The dew point (high humidity) alert occurs if the difference between the temperature and the dew
point is less than or equal to 3°C.
NOTE: The normal operating temperature inside the unit will be greater than the temperature
outside the back box due to the heat emitted by the system’s electronics.
RESET ALERT
Reset alert clears the alert condition and removes the alert label from the monitor. The system
automatically checks internal conditions 60 seconds after reset. If conditions are still
unacceptable, the alert label reappears on the screen indicating further corrective action is
required.
EXIT
SPECTRA IV
LANGUAGE
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
BACK
EXIT
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>
<CLEAR>
<PASSWORD>
<CLOCK>
<EVENT>
DOME SETTINGS
REPEAT
ACK ACTION
ACTIVATE AUX
<CURRENT READING>
RESET ALERT
BACK
EXIT
ALERT
TEMPERATURE
DEWPOINT
PRESSURE
REFRESH
BACK
EXIT
CURRENT READING