A SERVICE OF

logo

AUTOMATIC FILTERS INSTRUCTIONS MANUAL
FC/D - FAC/D
s.r.l.Milano - ITALY
Page 5 of 14
p11.02-v34.f fcd_mi-r1.doc
Whether raw water contains organics and/or is biologically polluted,
FAC/D
series filters
CANNOT
be used without written authorization by NOBEL Technical Department.
The activated-carbon bed also works as a mechanic filter same way of quartz-sand bed.
Although this working should be avoided, it can happen that the pressure drop of activated-
carbon bed reaches a value of 1 bar (100 kPa); in this case the backwashing of the filtering bed
is required.
The equipment allows to schedule the days (how often) and time of day for the regeneration,
same way of quartz-sand filters, as above explained.
It is recommended to run the regeneration only when it is strictly required: the backwashing
causes the mixing of the bed and could displace the higher layers of activated carbon (most
polluted) from the top to the bottom of the column.
During regeneration the water supplying is completely inhibited by means of a membrane
valve mounted on the outlet line.
3. Technical characteristics
3.1. Assumed raw water characteristics
water temperature (min÷max)
ºC (ºF) 5÷40 (41÷104)
water pressure (min÷max)
bar (kPa) 1.5÷8.0 (150÷800)
3.2. Technical characteristics (general)
power supply
V ph/Hz W 230 1/50 50
regeneration time
min. 20÷30
p min/max
bar (kPa) 0.2÷1.0 (20÷100)
3.3. Characteristics for each model
MODEL
connections
flow m³/h
backwashing water consumption
IN/OUT drain
operating max
backwash
liters
FC05/D
1¼" 1" 3.2 6.5 4.8 1600
FC08/D
1½" 1¼" 4.0 8.0 6.0 2000
FC11/D
1½" 1¼" 5.7 11.0 8.5 2850
FC15/D
2" 1½" 7.8 15.0 11.0 3900
FC20/D
2" 1½" 10.0 20.0 15.0 5000
FC25/D
2½" 2" 13.0 26.0 20.0 6500
FC30/D
DN80 2½" 16.0 32.0 24.0 8000
FC40/D
DN80 2½" 20.0 40.0 30.0 10000
FC45/D
DN80 2½" 23.0 46.0 35.0 11500
FC50/D
DN100 DN80 27.0 53.0 40.0 13500
FC60/D
DN100 DN80 31.0 62.0 46.0 15500
FC70/D
DN100 DN80 35.0 70.0 53.0 17500
FC80/D
DN100 DN80 40.0 80.0 60.0 20000