AUTOMATIC FILTERS INSTRUCTIONS MANUAL
FC/D - FAC/D
s.r.l.Milano - ITALY Page 14 of 14
p11.02-v34.f fcd_mi-r1.doc
9. Trouble shooting guide
PROBLEM CAUSE HOW TO SOLVE
The electronic programmer does not
switch ON.
electrical power is disconnected
the programmer is defected
connect electrical power
replace the programmer
The regeneration does not run electrical power is disconnected
the programmer is not correctly adjusted
the programmer is defected
connect electrical power
adjust correctly the programmer
replace the programmer
Regeneration is electrically started
but it does not run hydraulically
there is not supplying of pilot fluid (air or water)
one or more solenoyd valves are defected
connect properly the supplying of pilot water or
compressed air
replace the defected solenoyd valves
There is a leakage of water to drain
during service
one or both membrane valves no. 1 and 5 do not
close properly.
check the proper working of the pilot solenoyd valves
check and clean the seat of the plate of the
membrane valve
The unit does not feed water the membrane valve no. 2 does not open check the proper working of the pilot solenoyd valve
There is a leakage of filtering media
to the drain or to the outlet line
one nozzle of distribution system is damaged or
broken
replace the nozzle