INSTRUCTIONS MANUAL AUTOMATIC FILTERS
FC/D-DP -FAC/D-DP
s.r.l.Milano - ITALY
Page 20 of 20
fcd-dp_mi-r2.doc –
r.2
11. TROUBLE-SHOOTING GUIDE
PROBLEM CAUSE HOW TO SOLVE
The electronic
programmer does not
switch ON
electrical power is
disconnected
the programmer is defected
connect electrical power
replace the programmer
The regeneration does not
run
electrical power is
disconnected
the programmer is not correctly
adjusted
the programmer is defected
connect electrical power
adjust correctly the
programmer
replace the programmer
Regeneration is
electrically started but it
does not run hydraulically
there is not supplying of pilot
fluid (air or water)
one or more solenoid valves
are defected
connect properly the supplying
of pilot water or compressed air
replace the defected solenoid
valves
There is a leakage of
water to drain during
service
one among (or both)
membrane valves no. 1 and 5
does not close properly.
check the proper working of
the pilot solenoid valves
check and clean the seat of
the plate of the membrane
valve
The unit does not feed
water
the membrane valve no. 2 does
not open
check the proper working of
the pilot solenoid valve
There is a leakage of
filtering media to the drain
or to the outlet line
one nozzle of distribution
system is damaged or broken
replace the nozzle
The values of pressure
shown on the display of
the programmer are by far
different than the ones
gauged by manometers
the manometers are not quite
calibrated
the pressure transducers are
not quite calibrated i sensori di
pressione sono starati
check the real pressure values
by using a standard instrument;
then replace the instrument
(manometer or transducer)
which gauge the uncorrect
value *
* Normally, a difference of approx 3 % between the values gauged by the two different
measurement systems is acceptable.