![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/a/2c/a2c2dc6b-1c6e-41d6-8c19-a0d5008d16d9/a2c2dc6b-1c6e-41d6-8c19-a0d5008d16d9-bge.png)
INSTRUCTIONS MANUAL AUTOMATIC FILTERS
FC/D-DP -FAC/D-DP
s.r.l.Milano - ITALY
Page 14 of 21
fcd-dp_mi-r2.doc –
r.2
7. SETTINGS
7.1. How to set current time and day of the week
The programmer is equipped with internal clock, keeping exact time for 80 hours in case of
power failure. To set the current time and day, proceed as follows :
1. push the button
ESC
2. push the button until the pointer > indicates "Set …"
3. push the button
OK
4. the pointer indicates “Clock..”, push the button
OK
5. the pointer indicates “Set Clock..”, push the button
OK
6. push the button to point the day or the number to be modified
7. when the pointer blinks on the day or the number to be modified, push the buttonor
until the new desired day or value is shown (symbols related to days of week are
explained at following chapter)
8. repeat the same operation with other values, if required
9. push the button
OK
to confirm (save) the modifications
10. push twice the button
ESC
to go back to the visualization of service.
The programmer is already factory set for automatic updating with european summer time
(S/W Time ON = EU)
7.2. How to set day and time of regeneration
The days of the week can be set one by one; they appear on the display in the weekly row: it
is possible to select (visualized the initial letter of the day) or not (visualized the symbol -).
The row and explanation of the symbols that appear on the display are :
M / -T / -W / -T / -F / -S / -S / -
M
onday
T
uesday
W
ednesday
T
hursday
F
riday
S
aturday
S
unday
The available digits to set the time are between 00:00 and 23:59; the symbol --:-- indicate
not any ON and/or not any OFF.
The regeneration starts at the time set on the line ON.
The time on the line OFF
MUST BE NECESSARILY SET
one minute later than the time
on the line ON.
The programmer allows to set up to 3 regeneration per day (B3-1, B3-2, B3-3).