A SERVICE OF

logo

69-1037
5
T8411R ELECTRONIC HEAT PUMP THERMOSTAT
The temperature setpoint and the room temperature are
shown separately on the digital display. The indicator
points to Set when the temperature setpoint is displayed
and to Room when the room temperature is displayed.
Set
Room
INDICATOR
ROOM TEMPERATURE
SETPOINT TEMPERATURE
M11247
To set temperature setpoint:
1. Select heat or cool by sliding the SYSTEM switch
in the lower right corner of the thermostat to the
desired mode. See Fig. 7.
2. To display the setpoint temperature on the
digital display, press either the or key once.
The temperature setpoint is displayed for approxi-
mately five seconds as the indicator points to Set
and flashes.
M11248
3. To increase the setpoint temperature, press the
key. Press once to change the setpoint one
degree; press and hold to change the setpoint
several degrees.
M11249
4. To decrease the setpoint temperature, press the
key.
M11250
Setting
°
F/
°
C Indication and Heat Cycle Rate
NOTES: To save changes to the °F/°C indication and the
heat cycle rate, all seven steps must be
completed.
In installer setup mode steps 2. through 5., each
press of the key momentarily displays 01 and
each press of the key momentarily displays
02. When the keys are released, these two-digit
codes are no longer displayed.
To set the °F/°C indication and heat cycle rate:
1. If the room temperature is displayed in °F, set the
temperature setpoint to 52°F. If the room tempera-
ture is displayed in °C, set the temperature setpoint
to 11°C.
M11251
2. Press the ▲ ▼ keys simultaneously for more than
two seconds to light all segments on the display and
to enter installer setup mode. When the keys are
released, a two-digit software code is displayed
(code displayed may vary).
Optional System Checkout
CAUTION
When the heat or cool outputs are turned on, the
five-minute off-timer safety feature is bypassed.
When in steps
2.
and
3.
only, the
key can be
used to turn heat or cool outputs on. Change the
system switch setting to test heat or cool outputs.
No action takes place if the system switch is in
the Off position.
The following examples of system settings show a two
digit software code on the display. The code shown is only
an example; codes may vary.
System setting at Heat:
To turn heat on, press the key.
M11252
To turn auxiliary heat on, press the key.
To turn auxiliary heat off, press the key a third time.
To turn heat off, press the key a fourth time.
System setting at Cool:
To turn cool on, press the key.
To turn cool off, press the key.
3. Press the key. Factory information is displayed.
Information displayed varies by model. This
information is only for factory use.
M11469
Aux Ht
M11470
M11255
M11255
M11256
M11469
M11255