A SERVICE OF

logo

4-4
TYPICAL NON-CE BLOWER ASSEMBLY TYPICAL CE BLOWER ASSEMBLY
4.4 Adjusting the Burner Gas Pressure
DANGER
Frymaster recommends that ONLY qualified service personnel perform this task.
1. On Non-CE cookers, ensure that the gas valve knob is in the OFF position.
2. Remove the pressure tap plug from the gas valve assembly.
Typical Non-CE
Valve Assembly
Typical CE
Valve Assembly
Pressure Tap Plug
3. Insert the fitting for a gas pressure-measuring device into the pressure tap hole
4. On NON-CE cookers only, place the gas valve in the ON position.
5. Place the power switch in the ON position. When the burner has lit and burned steadily for at least one
minute, compare the gas pressure reading to the pressure for the corresponding gas in the appropriate
table below.