7
Program Control
Manual/Auto Dispense
• Each mode provides you access to different features on the liquid crystal
display. Use the Auto/Manual switch to move back and forth from
manual mode to automatic mode.
• In manual mode, you can use the foot pedal to dispense a deposit or bead
“by eye”. You are in manual mode when the Auto/Manual toggle switch
is in the downward position.
• In Automatic Dispense mode, you can set several variables, including
program number, syringe barrel size, deposit volume, dispense rate,
pullback, delay. You are in automatic dispense mode when the
Auto/Manual toggle switch is in the upward position.
Reverse Motion—Drawback
In manual mode, flip the Extend switch, located on the control panel, from
Extend to Retract to engage the motor in reverse direction. This will draw
fluid back into the reservoir stopping any ooze.
Hand Control
In both manual and auto mode, flip the Foot/Hand switch, from Foot to
Hand to operate the dispenser with a finger switch. Finger switches are
sold separately.