Fluid leakage Loose joints Tighten joints.
Dirty gasket Clean gasket and seat area.
Bad gasket Replace gasket.
Counter reading Calibration off Recalibrate meter.
high or low Air in product Find and repair air leaks in system.
Measuring chamber or gears sticking Clean or replace internal metering components.
Meter shaft seal Dirty seal Clean O-ring seal and seat area.
leakage Bad seal Replace seal.
TROUBLESHOOTING GUIDE
PROBLEM POSSIBLE CAUSE SOLUTION
9
ABOVEGROUND TANK INSTALLATION
NOTE:
USE APPROVED PIPE COMPOUND
ON ALL PIPE THREADS.
ELECTRICAL NOTE:
ELECTRICAL WIRING SHOULD BE DONE IN ACCORDANCE WITH APPROVED LOCAL
ELECTRICAL CODES AND BY A LICENSED ELECTRICIAN. THE PUMP SHOULD BE
PROPERLY GROUNDED, AND RIGID CONDUIT SHOULD BE USED WHEN INSTALLING
ELECTRICAL WIRING. WARNING: FAILURE TO FOLLOW THESE WIRING INSTRUCTIONS
MAY RESULT IN SERIOUS INJURY FROM ELECTRICAL SHOCK.