A SERVICE OF

logo

MDA 4V HD-SDI and SDI User's Guide • Introduction
MDA 4V HD-SDI and SDI User's Guide
10
MDA 4V HD-SDI and SDI User's Guide • Introduction
11
MDA 4V HD-SDI and SDI User's Guide • Specifications
MDA 4V HD-SDI and SDI User's Guide • Indicators
Indicators
DISTRIBUTION AMPLIFIER
DISTRIBUTION AMPLIFIER
MDA 4V HD-SDI
RATE
UNKNOWN
2.97 Gbps1.485 Gbps270 Mbps
31
2
Figure 10 — MDA 4V HD-SDI and SDI front panels
a
Power LED — Indicates power is applied.
b
Rate indicators (MDA 4V HD-SDI only) — These indicators
light to indicate the detected input video rate on the HD-SDI
input BNC connector. The recognized rates are 270 Mbps,
1.485 Gbps, or 2.97 Gbps.
c
Unknown rate indicator (MDA 4V HD-SDI only) — When lit,
this LED indicates that an input is detected on the HD-SDI input
BNC connector but that the MDA did not recognize the rate.
N
The MDA equalizes and distributes the input regardless
of whether the rate is recognized or not.
System operation
After the MDA and all of its connected devices are powered up,
the system is fully operational. If any problems are encountered,
ensure all cables are routed and connected properly.
Specifications
Video
Gain ................................................. Unity
Resolution....................................... 8 or 10 bits, automatic
Operation standards
MDA 4V HD-SDI ............... SMPTE-259M
SMPTE 292M
SMPTE 424M
ITU-R BT.601
ITU-R BT.1120
MDA 4V SDI ...................... 143 Mb/s (4f
sc
NTSC)
177 Mb/s (4f
sc
PAL)
270 Mb/s (4:2:2 component video)
360 Mb/s (4:2:2 widescreen component
video), autoselected
Equalization and re-clocking ....... Automatic for up to -30 dB of cable loss
Auto data rate lock
(MDA 4V HD-SDI) ............ Yes
Video input
Number/signal type
MDA 4V HD-SDI ............... 1 SDI, HD-SDI, or 3G-SDI digital
component video
MDA 4V SDI ...................... 1 SMPTE-259M serial digital component
video
Connectors ..................................... 1 BNC female
Data rates ........................................ 19 Mbps to 2.97 Gbps
Input cable equalization ............... Automatic
HD-SDI ............................... 120 m (400') using Extron RG6 cable
60 m (200') using Extron RG59 cable
SDI ....................................... 150 m (500') using Extron RG6 cable
120 m (400') using Extron RG59 cable
Nominal level ................................ 0.8 Vp-p
Minimum/maximum levels ........ 0.5 V to 1 Vp-p with no offset
Impedance ...................................... 75 ohms
Return loss
MDA 4V HD-SDI ............... <-15 dB @ 5 MHz to 2.97 GHz
MDA 4V SDI ...................... <-15 dB @ 5 MHz to 270 MHz
Maximum DC offset ..................... 5 V
Input coupling ............................... AC
Specs file: MDA_4V_HD-SDI_D2_060607.PMD and MDA_4V_SDI_D7_081904.PMD