3.4 Front Panel
1. Ethernet For connection to a PC or to an Ethernet hub or switch; LEDs indicate connection status.
2. U-Net Indicators LEDs indicate U-Net status.
3. Input Channels A to D Selects the input channel for display of or editing its parameters selected by a Function button.
4. Input Channel Meters Provides input metering after the ADC (analog to digital converter).
5. Input Channel Mutes Mutes the output signal of the corresponding input channel.
6. LCD Display Displays parameters for function selected by the function buttons.
7. Encoder Knob Joystick control for navigating menus and changing parameter settings.
8. Function Buttons Selects the function to be displayed or edited in the LCD display.
9. Output Channels 1 to 8
Selects the output channel for display of or editing its parameters selected by a Function button.
10. Output Channel Meters
Provides output metering before the DAC (digital to analog converter).
11. Output Channel Mutes
Mutes the signal and U-Net outputs of the corresponding output channel.
3.5 Rear Panel
12. IEC Receptacle ac mains input, 100 V to 240 V, 50 Hz to 60 Hz.
13. ac mains fuse 4 A, slow-blow (main and spare in IEC Receptacle drawer).
14. Power ac mains on and off.
15. Outputs 1 to 8 XLR connectors for audio outputs (analog).
16. Inputs A to D XLR connectors for audio inputs (analog for A to D or AES/EBU for A & C only).
17. U-Net 1 and 2 Network ports for audio input, audio output, and control connections to additional
UX8800s and other U-Net enabled products.
Page 4