Toshiba SL-9000-LSB Scale User Manual


 
11-25
11. PROGRAMMING PROCEDURES
2. When the ENTER key is passed, bar code format is checked. An error occurs in the
following cases.
Check digit (C/D) is at other than digit-13.
Price check digit (PC/D) cannot be calculated. (Price is other than 4 or 5 digits.)
Price is not set serially beginning from P1 to P4, or P1 to P5).
Weight is not set serially beginning from W1 (W1 to W5).
3. The usable keys to set the column are as follows:
11.15 BAR CODE FORMAT
PLU # 123456
Display HHHHHH
123456
FLAG 0 ~ 9
PLU # 1 ~ 6
UPC# 1 ~ 6
PC/D 1
PRICE 1 ~ 6
WEIGHT 1 ~ 6
C/D 1
4. Digits and display of PLU# 5. Digits and display of UPC#
6. Digits and display of price
UPC # 123456
Display CCCCCC
123456
7. Display of weight Digits
8. Setting Items
PLU # $ 1 2 . 3 4
Display P P P P
12 34
$ 1 2 3 . 4 5
PPP PP
123 45
Weight 1 2 . 3 4 5 lb
Display W W W W W
12 345
Weight 1 2 . 3 4 5 kg
Display W W W W W
12 345
Flag PLU# UPC# PC/D
C/D Weight Price
1
2
3
4
5
6
7