13. OPERATING PROCEDURES
13.6 TARE/SAVE FUNCTION PROCEDURES
13-11
13.6 TARE/SAVE FUNCTION PROCEDURES
Menu: REG., M.DOWN, or REWRAP
Mode: WEIGH or FIX (Tare % function is available in WEIGH mode only.)
NOTES: 1. Tare subtraction is available up to 2.000 lb. for the US type, and up to 1.000kg (2.205lb) for the CA/QR type. When
tare subtraction is in operation, however, the scalable range for net weight becomes less by the amount of the tare.
(Net weight=Gross weight-Tare)
2. Preset tare must be a multiple of 2 g for CA/QR type (Kg scale) and a multiple of 0.005 lb for US/CA type (Lb scale).
3. The tare % function is available when the Initial Setting #8-7 is set to 1 (SL-9000) or #28-4 is set to 1 (SL-9000N). The
speed key #108 will function as the % key (Refer to page 5-3). Set a tare % within the range from 0.0 to 99.9.
4. When a commodity is placed on the platter and the calculated tare exceeds the maximum, a TARE WEIGH OVER
error will occur.
There are two kinds of tare subtraction procedures, one is “Direct tare”, the other is “Preset tare ”The
key is used to save the tare, unit price, and PLU data after taking a commodity from the platter.
SAVE
0.200 lb
Place a container on
the platter.
(Ex. 0.200 lb)
Enter the PLU #.
Press:
The PLU data and tare are
saved.
Place a commodity on the
platter.
(Ex. 1.000 lb)
T
1 0 0
SAVE
PLU
Place a container
on the platter
2 0 0
T
Press:
The label is issued.
Remove the commodity
together with the container.
C
MANUAL:
:AUTO
Press:
Press:
PLU
T
PLU
Press:
Press:
Press:
Press:
CA type
US type
0
Press:
Remove the Commodity
together with the container.
PRT
*
C
%
1 0 0
%
1 0 0
%
Tare %
Tare %