Sunrise Medical Quickie P120 Mobility Aid User Manual


 
37
930373 Rev. B
36
930373 Rev. B
XI. BATTERIES
E. CHARGING BATTERIES
To avoid the risk of severe injury or death from electrical shock,fire or explosion
while charging:
1. Never connect charger to a 240 volt source.The main input voltage is 110 volts.
2. Never touch the charger after it is connected to an electrical outlet.This may cause
electrical shock.
Connect charger to the power supply ONLY AFTER you connect charger to
the battery.
Never connect or disconnect charger from battery while there is power to
the charger.
3. Never use an extension cord.Use of an improper cord could damage the charger,or
cause a fire or electrical shock.
4. Do not use charger if it has been dropped or damaged.
5. A battery emits explosive hydrogen gas during charging.To reduce the risk of fire
or explosion:
Make sure area is well vented. Never charge battery in a closed-in area.
Never smoke or allow a spark,flame or high heat near battery during changing.
Never allow metal tools or chair parts to contact battery.
6. Never look directly into cells when charging battery.
1. Use the charger that comes with your wheelchair.Read and follow all
instructions and warnings.
2. Use the correct switch setting (located on the charger) for the type of
batteries being used (wet or gel).
3. Make sure room is well ventilated.
4. Turn off all power to your chair.
5. Connect and disconnect battery cables with caution. Only connect the charger
to the power supply after the charger has been connected to the chair
6. Make sure to allow enough time to fully charge batteries.
Note: Batteries should never be left for long periods in the discharged state.Unused or
stored batteries should be given a charge once per month.
C. ACID BURNS
Acid in batteries is corrosive. It can cause serious burns to the eyes and skin
and can damage floors, furniture, clothing and your wheelchair.
1. Use extreme care not to spill acid when you handle batteries.
Keep batteries upright.
2. Avoid contact of acid with bare skin or clothing.
3. Always wear rubber gloves and safety glasses when you handle batteries.
4. If acid contacts your skin or clothing, wash immediately with soap and water.
5. If acid contacts your eyes,immediately flood eyes with cold running water for at least
15 minutes.Seek medical attention immediately.
D. CONNECTING BATTERIES IN BATTERY BOX(ES)
1. Batteries weigh up to 40 lbs.Take care to avoid injury when lifting.
2. Keep batteries upright.Take care not to spill acid.
3. Always wear rubber gloves and safety glasses when you handle batteries.
4. Before handling, remove all metal personal effects,such as neck laces,rings, pens and
other metal jewelry that might contact battery and cause a short.
XI. BATTERIES
Never make direct contact across both battery terminals,as an explosion may occur.
A spark may result in an explosion and/or fire resulting in severe injury or death.
1. Lift battery into battery box base.
2. Connect and disconnect battery cables
with caution. Connect the red lead to the
positive terminal and the black lead to the
negative terminal.In the single (UI) battery
box connect the red lead to a different
battery than the black lead.Connect the
remaining positive terminal to the negative
terminal at the other battery using the
range jumper connector.
3. Tighten all the terminal fasteners using
two wrenches.
4. Place the battery lids on the bases and
secure with the battery box strap.
5. Place battery box into battery cage.
Connector on box lid should face the chair.
6. Connect the harness lead to the battery
box connector on the lid.
7. Lift the battery cage on to the locating pins
found on the gear boxes. Make sure cage is
seated properly.
8. Lock the battery cage into place by pushing
down on the battery cage handle.