4
Factors affecting readings
The analysis is based on a measurement of the
electrical body resistance. Eating and drinking
habits during the day and private lifestyles influence
the body’s fluid balance.
This is noticeable by fluctuations in the readings.
To obtain analysis results that are highly precise and
iterative, make sure that the measurement conditi-
ons are constant. Only then will you be able to ob-
serve changes precisely over a long period of time.
In addition, other factors may affect fluid
balance:
After a bath the indicator will display a body
fat percentage that is too low and a body water
percentage that is too high
After a meal the indicator may be higher
Women are subject to fluctuations due to their
menstrual cycle
Body fluids are lost due to illness or after bodily
exertion (sport) After sporting activity, you
should wait for a period of 6 to 8 hours before
taking the next measurement
Anomalous or implausible readings may occur
in the following situations:
Persons with fever, oedema symptoms or
osteoporosis
Persons weighing over 150 kg
Persons with a body fat portion of more
than 50%
Persons undergoing dialysis therapy
Persons taking cardiovascular medication
Pregnant women
Athletes who do more than 10 hours of intensive
training a week and have a resting heart rate
under 60 bpm
Competitive athletes and body builders
Young people under 17 years old
Technical data
Weighing range: 180 kg
Division: 100 g
Operating temperature: 15°C bis 35°C
Max. air humidity: 85%
Storage temperature: –30° bis 70°C
Power supply: power adapter input
100–240V AC,
output 7,5V DC,
protection class IP 54
Battery: Lithium battery CR2032,
3V for the power supply
of time and date settings
Printer: thermal printer, paper
width 58 mm
Print paper: thermal paper outside layer,
49,5 mm wide, max. roll
diameter 50mm, commer-
cially available, Order Num-
ber from Soehnle Professio-
nal 2500.01.008
(pack containing 10 rolls)